Technology - Paper 1

Technology - Paper 1

1 / 40

1. To feed a 400v motor the voltage Stepped down from the sub-station would be...

2 / 40

2. Which one is not a Transmission voltage?

3 / 40

3. Which is the worst way of using Harvested Rainwater?

4 / 40

4. What is Grey water best used for?

5 / 40

5. A Micro-wind turbine swept area is no more than (max 2.2m blades).

6 / 40

6. What Fossil fuel is used to produce steam?

7 / 40

7. Which is the best location for wind turbines?

8 / 40

8. Which one doesn’t need Fossil fuel to produce steam?

9 / 40

9. Which one of the following is the main fuel for Biomass?

10 / 40

10. Name the Earthing system in the picture.

11 / 40

11. Name the Earthing System in the picture.

12 / 40

12. Name the Earthing System in the picture.

13 / 40

13. What type of Earthing systems is this?

14 / 40

14. What type of Earthing Systems is this?

15 / 40

15. What type of Earthing Systems is this?

16 / 40

16. The Earth return path within the suppliers cable of a TN-C-S System is the...

17 / 40

17. Name the following fixing…

18 / 40

18. Which correction factor is used for Grouping of cables?

19 / 40

19. Which protective device would protect against Overload and Earth Fault protection?

20 / 40

20. Which protective device would not protect against Overload protection?

21 / 40

21. Why is a copper link used when joining two pieces of Steel trunking?

22 / 40

22. What type of conduit would be used as a cpc?

23 / 40

23. Which protective device would protect against Earth Fault protection?

24 / 40

24. What would be a cheap way of installing an SWA 4 core cable to a Distribution board?

25 / 40

25. Which DATA cable would be used if there are lots of computers in use?

26 / 40

26. What would be the minimum size of trunking for single core 70º thermoplastic insulation cables: 10 x 4mm², 10 x 4mm², 10 x 10mm².

27 / 40

27. What is the minimum conduit size for a straight run containing the following single core thermoplastic insulation cables, 2 x 1.5mm2, 3 x 2.5mm2 and 3 x 4mm2.

28 / 40

28. What is the symbol shown below?

29 / 40

29. What is the symbol shown below?

30 / 40

30. If Band 1 and Band 2 circuits are in the same trunking they must be…

31 / 40

31. What would be the voltage drop for a two-core 2.5mm2 700Thermoplastic insulated and sheathed flat cable feeding a load of 18A and the length is 22m?

32 / 40

32. What is EWR used for?

33 / 40

33. Which one of the following is a Statutory document?

34 / 40

34. What document would list lighting, fittings, type and size of cables?

35 / 40

35. When using tools and electrical equipment what regulations would cover these?

36 / 40

36. Which one of these defines a metal radiator which is fixed to a wall?

37 / 40

37. Which one of these defines a metal conduit which is fixed to a wall where it drops down to a light switch?

38 / 40

38. Which one of the following is the most common material used for cables suspended by pylons used for transmission systems?

39 / 40

39. what is the maximum length of span for cables between buildings with no intermediate support?

40 / 40

40. what is the minimum internal radii factor for cable bends if the cable has less than 10mm diameter?

Your score is

The average score is 68%

Technology - Paper 2

Technology - Paper 2

1 / 30

1. The electricity at work regulations?

2 / 30

2. To complete a cable calculation for a fire alarm circuit, I would need?

3 / 30

3. What doesn’t need connecting to the M.E.T?

4 / 30

4. In the code BS EN 60898, EN stands for?

5 / 30

5. Which diagram is usually drawn left to right?

6 / 30

6. An example of a 1:20 scale on a diagram could be?

7 / 30

7. To keep stock of materials on site, it would be good to have?

8 / 30

8. Fire alarm call points are normally wired?

9 / 30

9. Which wiring system could have XLPE incorporated in it?

10 / 30

10. Which system is best for connecting to a motor?

11 / 30

11. When installing Galv steel conduit you must consider?

12 / 30

12. A high circuit volt drop would need?

13 / 30

13. The lowest acceptable volt drop for a 230V cooker circuit would be?

14 / 30

14. The highest percentage of volt drop allowed for 230V lighting circuits is?

15 / 30

15. Mutual detrimental influences doesn’t cover? 

16 / 30

16. A socket fixed outside must have?

17 / 30

17. Earthing of bathroom pipes is called?

18 / 30

18. A T.T system always contains?

19 / 30

19. In a TN-S system where are the neutral and earth connected together?

20 / 30

20. What causes an RCD to operate?

21 / 30

21. Which part of an MCB operates under fault conditions?

22 / 30

22. What’s the first step of a safe isolation procedure?

23 / 30

23. Which best describes GS38?

24 / 30

24. The most common tool used with steel conduit is?

25 / 30

25. Construction site power tools are normally?

26 / 30

26. Recessed light fittings must?

27 / 30

27. Fluorescent lamps contain?

28 / 30

28. Which type of mcb is design for small motor protection?

29 / 30

29. The insulation inside an MICC cable is?

30 / 30

30. The BS number for re-wireable fuses is?

Your score is

The average score is 61%

Technology - Paper 3

Technology - Paper 3

1 / 24

1. Which of the following is statutory?

2 / 24

2. For which of the following jobs do you not need to follow a code of practice?

3 / 24

3. Which diagram may contain exploded views?

4 / 24

4. In which year did the IET 18th Ed come out?

5 / 24

5. Which lamp is best for low current use?

6 / 24

6. Which earthing system relies upon a concentric cable for an earth path?

7 / 24

7. What operates bimetal strip?

8 / 24

8. The maximum temperatures for PVC and heat proof flex cables are respectively?

9 / 24

9. For cables buried diagonal in chases it is recommended to fit what over the cable?

10 / 24

10. Which correction factor would apply to cables surrounded in thermal insulation?

11 / 24

11. The switched lines in two way switching are known as?

12 / 24

12. What is the purpose of local isolation for motors?

13 / 24

13. D.O.L are types of?

14 / 24

14. Breakers are better than fuses because they are?

15 / 24

15. What does a maintained emergency light have that a standard light hasn’t?

16 / 24

16. Where does a fire alarm zones monitoring resistor go?

17 / 24

17. An isolator used in petrol stations is known as a ?

18 / 24

18. Why would a cable be coloured black?

19 / 24

19. If an A2 radial keeps within a floor area of 75m it can have?

20 / 24

20. An A3 radial circuit can be supplied by a maximum device size of?

21 / 24

21. What is the benefit of larger conduit?

22 / 24

22. The trunking for feeding different floors of high rise buildings is called?

23 / 24

23. A useful fixing for brick walls is?

24 / 24

24. The best cable for burying in warm ground is?

Your score is

The average score is 71%

Technology - Paper 4

Technology - Paper 4

1 / 24

1. Which of the following is non-statutory?

2 / 24

2. For which of the following jobs don’t you need to follow a code of practice?

3 / 24

3. Which diagram contains architectural symbols?

4 / 24

4. In which year did the electricity at works regs come out?

5 / 24

5. Which lamp is best for tropical plants?

6 / 24

6. Which earthing system relies upon the soil for an earth path?

7 / 24

7. What operates an RCD?

8 / 24

8. The maximum temperatures for PVC and XLPE cables are respectively?

9 / 24

9. For cables buried in chases it is recommended to fit what over the cable?

10 / 24

10. Which correction factor would apply to bunching SWA cables on cable tray?

11 / 24

11. 3 phase terminations should be labeled?

12 / 24

12. What is the main purpose of star-delta starting for motors?

13 / 24

13. D.O.L stands for?

14 / 24

14. Cartridge fuses are better than breakers because they can take more what?

15 / 24

15. What does a maintained emergency light have that a standard light hasn’t?

16 / 24

16. What does a fire alarm zone need to monitor it’s health?

17 / 24

17. A break glass is also known as a ?

18 / 24

18. Why would a cable be coloured red?

19 / 24

19. If an A1 ring keeps within a floor area of 100m it can have?

20 / 24

20. An A3 radial circuit has a maximum floor area of?

21 / 24

21. After too many bends or too much length in conduit it is advisable to have?

22 / 24

22. The popular under floor trunking for sockets is called?

23 / 24

23. A useful fixing for plasterboard ceilings is?

24 / 24

24. If my girders cant take the weight what cable is best for a large dist board?